AVTECH AVN244V or AVN284V ONVIF on Synology

Posted on September 15, 2012 by admin

I have the AVTECH AVN-244V/284V, is ONVIF compatible camara. This camara live correct but i not have control to Zoom and PT becouse not found.

* Solution:
1)Very important, FIRST put in th Camara webbrowser -> General -> On line -> “Anonymous Viewer Login: Enable”
and “Login with CAPTCHA Image:Off”

2) Firmware update to 1079 or more:
ftp://211.75.84.102/Firmware/AVN284V_1079.rar
ftp://211.75.84.102/Firmware/AVN244V_1079.rar

3) Are you sure that you have the 1079?
Check it
if not try again with the software that has avtech called “VideoViever”
ftp://211.75.84.102/AP/Video_Viewer/VideoViewer_Setup_M0183.rar

4)Put new camara with ONVIF -> ok

Edit
/volume1/@appstore/SurveillanceStation/conf/camera_model.conf

AVTECH*AVN244=AVTECH*generic to the camlist

Ad the following to the bottom of the camera commands list.

[AVTECH*generic]
video source=/cgi-bin/guest/Video.cgi?media=mjpeg
tilt up=”cgi-bin/user/Serial.cgi?action=write&device=MASTER&channel=1&data=07%20D0%201%2055%204B%20EF%20FF%205F%2000%2023%22″
tilt down=”/cgi-bin/user/Serial.cgi?action=write&device=MASTER&channel=1&data=07%20D0%201%2055%204B%20DF%20FF%204F%2000%2023%22″
pan left=”cgi-bin/user/Serial.cgi?action=write&device=MASTER&channel=1&data=07%20D0%201%2055%204B%20BF%20FF%202F%2000%2023%22″
pan right=”cgi-bin/user/Serial.cgi?action=write&device=MASTER&channel=1&data=07%20D0%200%2055%204B%207F%20FF%20FF%2000%2023%22″
home pos=”cgi-bin/user/Serial.cgi?action=write&device=MASTER&channel=1&data=07%20D1%201%2055%204B%20FF%20EF%205F%2000%2023%22″
zoom in=”cgi-bin/user/Serial.cgi?action=write&device=MASTER&channel=1&data=07%20D0%201%2055%204B%20FE%20FF%206F%2000%2023%22″
zoom out=”cgi-bin/user/Serial.cgi?action=write&device=MASTER&channel=1&data=07%20D0%201%2055%204B%20FD%20FF%206D%2000%2023%22″